国产三级伦理在线,久久久久黄久久免费漫画,成人国产精品日本在线,欧美美最猛性xxxxxx

西門子NCU573.2
西門子NCU573.2
產(chǎn)品價(jià)格:¥22(人民幣)
  • 規(guī)格:進(jìn)口原裝
  • 發(fā)貨地:上海
  • 品牌:
  • 最小起訂量:1臺(tái)
  • 免費(fèi)會(huì)員
    會(huì)員級(jí)別:試用會(huì)員
    認(rèn)證類型:未認(rèn)證
    企業(yè)證件:未通過
    認(rèn)證信息:未認(rèn)證

    商鋪名稱:上海啟水自動(dòng)化科技有限公司

    聯(lián)系人:李明松(先生)

    聯(lián)系手機(jī):

    固定電話:

    企業(yè)郵箱:shanghailms888@163.com

    聯(lián)系地址:上海市松江區(qū)樂都路251號(hào)樂都大廈16G

    郵編:201600

    聯(lián)系我時(shí),請(qǐng)說是在焊材網(wǎng)上看到的,謝謝!

    商品詳情

      西門子NCU573.2
      NCU  573.5/573.4/573.3/573.2/572.5/572.4/572.3/572.2/571.5/561.5/571.4/571.3/571.2

      上海啟水自動(dòng)化科技有限公司(西門子核心分銷商)

       聯(lián)系人 :李 松( 銷售經(jīng)理 24小時(shí)服務(wù)熱線 186 0165 7819

       電話( Tel ): 021-60641328    

      工作( Q Q  1471187088 郵箱( Email )::1471187088@qq.com  

       地址( Add ):上海市松江區(qū)弘翔路58號(hào)195

      公司優(yōu)勢(shì)產(chǎn)品系列=西門子S7-200CN | S7-300PLC |  觸摸屏 | 變頻器 | 伺服電機(jī) | 數(shù)控系統(tǒng) | 總線電纜| 開關(guān)電源

       
      SINUMERIK 840D/DE BOX FOR ELECTRONIC CONTROL DEVICE NCU BOX FOR INSTALLATION OF NCU 561.2/.3/.4/.5 NCU 571/571.2/.3/.4/.5 NCU 572/572.2/.3/.4/.5 NCU 573.2/.3/.4/.5 WITH POWER UNIT, BATTERY AND FAN

      Technical specifications

      Order No.

      6FC5356-0BB15-0AA0

      6FC5357-0BB15-0AA0

      6FC5357-0BB25-0AA0

      6FC5357-0BB35-0AA0

      Product name

      SINUMERIK 840D powerline NCU 561.5

      SINUMERIK 840D powerline NCU 571.5

      SINUMERIK 840D powerline NCU 572.5

      SINUMERIK 840D powerline NCU 573.5

      Processor

      Celeron

       

       

      Pentium III

      SIMATIC S7 - integrated

      PLC 317-2 DP

      Input voltage

      Via SIMODRIVE device bus

      Degree of protection according to EN 60529 (IEC 60529)

      IP20 (with NCU box)

      Humidity rating in accordance with EN 60721-3-3

      Class 3K5 condensation and icing excluded. Low air temperature 0 °C (32 °F).

      Relative humidity

       

       

       

       

      • Storage

      10 ... 95 %

       

       

       

      • Transport

      10 ... 95 %

       

       

       

      • Operation

      < 95% for 1h, annual average < 65%

      Ambient temperature

       

       

       

       

      • Storage

      -20 … +60 °C (-4 ... +140 °F)

       

       

       

      • Transport

      -20 … +60 °C (-4 ... +140 °F)

       

       

       

      • Operation

      0 … 55 °C (32 ... 131 °F)

       

       

       

      Dimensions

       

       

       

       

      • Width

      50 mm (1.97 in)

       

       

       

      • Height

      316 mm (12.4 in)

       

       

       

      • Depth

      207 mm (8.15 in)

       

       

       

      Weight,approx.

      0.72 kg (1.59 lb)

       

       

      1.05 kg (2.32 lb)

      Approvals

      CE, cULus

       

       

       


      Ordering data:
        

      Release (only as spare part)
      (product status: Cancellation/discontinuation):

      6FC5357-0BB23-0AA0


      (predecessor:
      6FC5357-0BB22-0AE0)

      SINUMERIK 840DE
      NCU 572.3, 400 MHZ, 64 MB
      WITHOUT SYSTEM SOFTWARE
      MEMORY: NC 0.5MB, PLC 96KB
      PROFIBUS-DP PREPARED
      ACCORDING TO IEC 61508

      6FC5357-0BB33-0AA0


      (predecessor:
      6FC5357-0BB33-0AE3)

      SINUMERIK 840D/DE
      NCU 573.3, 650 MHZ, 64 MB
      WITHOUT SYSTEM SOFTWARE
      MEMORY: NC 2.5MB, PLC 96KB
      PROFIBUS-DP PREPARED
      ACCORDING TO IEC 61508



      NCU system software, compatibility:

        Hardware

      NCU system software, compatibility subsequently tested

        NCU 572.3

       

      6FC5357-0BB22-0AE0

         12-axis software:
        6FC520-_BY30-_AH_
        6FC520-_BX30-_AH_

        SW4.4 from V04.04.38
        SW5.3 from V05.03.08
        all SW6.x

      6FC5357-0BB23-0AA0

        SW4.4 from V04.04.39
        SW5.3 from V05.03.42
        all SW6.x

        NCU 573.3

       

       

      6FC5357-0BB33-0AE2

        12-axis software:  
        6FC520-_BY30-_AH_
        6FC520-_BX30-_AH_

        31-axis software:
        6FC520-_AY30-_AH_
        6FC520-_AX30-_AH_

         all SW4.x
        all SW5.x
        all SW6.x
        all SW7.x

      6FC5357-0BB33-0AE3

        SW4.4 from V04.04.39
        SW5.3 from V05.03.18
        all SW6.x
        all SW7.x
        (see also !18682807!)

      6FC5357-0BB33-0AA0

        SW4.4 from V04.04.39
        SW5.3 from V05.03.42
        all SW6.x
        SW7.2 from 07.02.07


      Strategy in the spare parts business:

      NCU 572.3
      Predecessor  6FC5357-0BB22-0AE0  =>  successor  6FC5357-0BB23-0AA0

      NCU 573.3
      Predecessor  6FC5357-0BB33-0AE3  =>  successor  6FC5357-0BB33-0AA0

      If there is no compatibility with the NCU software, the previous component should be used – or if this is no longer available, then an upgrade should be made to the specified update status or to the next higher update status in the meantime.

      Depending on the inventory in the spare parts loop, spare part supply, supply as exchange and/or repair will be considered.


      Strategy in the new part business:

      NCU 572.3  =>  NCU 572.4 (or NCU 572.5)
      Predecessor  6FC5357-0BB22-0AE0  =>  successor  6FC5357-0BB24-0AA0
                                                                 or 6FC5357-0BB25-0AA0

      NCU 573.3  =>  NCU 573.4 (or NCU 573.5)
      Predecessor  6FC5357-0BB33-0AE3  =>  successor  6FC5357-0BB34-0AA0
                                                                 or 6FC5357-0BB35-0AA0

      The NCU *.3 components have been cancelled/discontinued effective 30.09.2004. The new replacement components in the new part business will be NCUs with integrated PLCs with a higher performance (NCU *.4 with integrated PLC 314C-2DP or NCU *.5 with integrated PLC 317-2DP):
       

      PLC parameters

      315-2DP
      NCU *.3

      314C-2DP
      NCU *.4

      317-2DP
      NCU *.5

      Processing time in ms/kI (1 kI = 1024 instructions, corresponds to approx. 3 kbytes)
      - for bit commands (minimum)
      - for commands (minimum)
      Factor for cycle time for
      user programs 1)



      0.3
      1.0

      1



      0.1
      0.25

      0.35



      0.03
      0.1

      0.12

      PLC user memory in kbytes,
      basic version
      max. expansion


      96
      288


      96
      480


      128
      768

      No. of FBs, FCs

      Each 256

      Each 256

      2048 2)

      No. of DBs

      399

      399

      20472)

      No. of timers

      128

      256

      512

      No. of counters

      64

      256

      512

      I/O scope for cyclic process image

      Each 128

          Each 128

      Each 256

      I/O scope for the complete logical I/O address space

      Each 1024

      Each 1024

      Each 4096 3)

      Max. number of Profibus slaves

      63

      32

      125

       

      Comments:

      1)

      The increase in performance refers to the computational performance available. Depending on the technological/process-related conditions, this increase in performance is included in the total result. A faster IPO clock cycle (as a result of faster processors) and lower PLC cycle times result, partially, in significantly improved technological/process-related results; e.g. shorter unit/clock cycle times, higher speeds for eccentric turning, higher feed rates for mould construction.

      2)

      The number specified is the upper address number that can be used; the maximum number of FBs, FCs and DBs is, as a total, 2048!
      Reserved addresses should be taken into account; refer to the current documentation.

      3)

      4096 additional I/O addresses are available and can be seen in STEP 7; however these addresses are reserved for future applications. For compatibility reasons, these addresses may not be used. 
      The diagnostic addresses (presently at the upper end 1023, 1022) must be appropriately marshaled in the PLC project; refer to the current documentation.

      Brief instructions: (prerequisites: SIMATIC know-how; STEP 7)
      When changing-over from an NCU with PLC315-2DP to an NCU with PLC 314C-2DP or PLC317-2DP, in the hardware configuration in the module catalog, the matching Rack0 should be selected under "SIMATIC 300\SINUMERIK\810D / 840D".
      Further it should be checked as to whether a Profibus diagnostics block of A&D AS (FC125 or FB125) is used. These blocks must be brought up to the actual version (V4.9).

    在線詢盤/留言
  • 0571-87774297  