SHINHO星河SHN-ASC-3ACC-U,出售云永WYFN3H3C80R4CREVIS,RT-4564,ACREVIS,NAlog Output 4 Channels, -10~10V, 15Bit
CREVIS,RT-4544,ACREVIS,NAlog Output 4 Channels, -10~10V, 14Bit
CREVIS,RT-4524,ACREVIS,NAlog Output 4 Channels, -10~10V, 12Bit
CREVIS,RT-4468,ACREVIS,NAlog Output 8 Channels, 0~10V, 15Bit
CREVIS,RT-4464,ACREVIS,NAlog Output 4 Channels, 0~10V, 15Bit
CREVIS,RT-4448,ACREVIS,NAlog Output 8 Channels, 0~10V, 14Bit
CREVIS,RT-4444,ACREVIS,NAlog Output 4 Channels, 0~10V, 14Bit
CREVIS,RT-4428,ACREVIS,NAlog Output 8 Channels, 0~10V, 12Bit
CREVIS,RT-4424,ACREVIS,NAlog Output 4 Channels, 0~10V, 12Bit
CREVIS,RT-4258,ACREVIS,NAlog Output 8 Channels, 4~20CREVIS,MA, 15Bit
CREVIS,RT-4254,ACREVIS,NAlog Output 4 Channels, 4~20CREVIS,MA, 15Bit
CREVIS,RT-4238,ACREVIS,NAlog Output 8 Channels, 4~20CREVIS,MA, 14Bit
CREVIS,RT-4234,ACREVIS,NAlog Output 4 Channels, 4~20CREVIS,MA, 14Bit
同時由于起動轉矩較大,將對負載產生沖擊,傳動部件的磨損和額外。所以當電機的容量較大(一般為超過電源容量的20%—30%時)均采用降壓起動。上采用的降壓起動的有Y/△換接起動和自耦變壓器降壓起動。雖然這兩種起動均可起動電流,但是在降壓起動完成后的分檔投切和加全壓的瞬間,仍將產生數倍額定電流的尖峰電流(二次沖擊電流),此電流將對配電造成沖擊,同時產生的性的動態轉矩會引起水泵電機的機械震動,對電機的轉子、中間齒輪等非常有害,并使供電線路電耗增大。軟啟動器也是降壓起動器的一種。它是利用性能先進的微處理器,合理有序地控制大功率晶閘管組件導通,使之產生逐步的的交流電壓加在交流電動機上。凸出式插拔式結構,嵌入式插拔結構等,并有的塑料外罩,可以觀察繼電器的整定值和規格等。電磁式電壓繼電器磁有兩個線圈,線圈出頭接在底座端子上,用戶可以根據需要串并聯,因而可使繼電器整定范圍變化一倍。電磁式電壓繼電器銘牌的刻度值及額定值對于電流繼電器是線圈串聯時的電流(以A為單位),對于電壓繼電器是線圈并聯時的電壓(以V為單位)。轉動刻度盤上的指針,以改變游絲的反作矩從而可以改變繼電器的值。電磁式電壓繼電器的:對于過電流(壓)繼電器,電流(壓)升至整定值或大于整定值時,繼電器就,動合觸點閉合,動斷觸點斷開。當電流(壓)到0.8倍整定值時,繼電器就返回,動合觸點斷開,動斷觸點閉合。
CREVIS,RT-4218,ACREVIS,NAlog Output 8 Channels, 0~20CREVIS,MA, 12Bit
CREVIS,RT-4214,ACREVIS,NAlog Output 4 Channels, 0~20CREVIS,MA, 12Bit
CREVIS,RT-4158,ACREVIS,NAlog Output 8 Channels, 0~20CREVIS,MA, 15Bit
CREVIS,RT-4154,ACREVIS,NAlog Output 4 Channels, 0~20CREVIS,MA, 15Bit
CREVIS,RT-4138,ACREVIS,NAlog Output 8 Channels, 0~20CREVIS,MA, 14Bit
CREVIS,RT-4134,ACREVIS,NAlog Output 4 Channels, 0~20CREVIS,MA, 14Bit
CREVIS,RT-4118,ACREVIS,NAlog Output 8 Channels, 0~20CREVIS,MA, 12Bit
CREVIS,RT-4114,ACREVIS,NAlog Output 4 Channels, 0~20CREVIS,MA, 12Bit
CREVIS,RT-3944,4 Channels, Differential Voltage Input, 0~10V, 4~5V, -10~10V, -5~5V, 15bit
CREVIS,RT-3934,4 Channels, Differential Current Input, 0~20CREVIS,MA, 4~20CREVIS,MA, -20~20CREVIS,MA, 15bit
CREVIS,RT-3924,4 Channels, Differential Voltage Input , 0~10V, 0~5V, -10~10V, -5~5V, 12bit
CREVIS,RT-3914,4 Channels, Differential Current Input, 0~20CREVIS,MA, 4~20CREVIS,MA, -20~20CREVIS,MA, 12bit
CREVIS,RT-3804,ACREVIS,NAlog Input 4 Channels, Thermocouple
CREVIS,RT-3704,ACREVIS,NAlog Input 4 Channels, CREVIS,RTD, CREVIS,STatus
首先檢查各接線接口是否出現松動,然后檢查串口及中斷號是否有沖突,如果是由于沖突引起的,那么應資源,避開沖突。其次,檢查人機界面表面是否出現裂縫,如發現有裂縫應及時更換。此外,還需要檢查人機界面表面是否有塵垢,若有,用軟布進行。觀察檢查控制盒上的指示燈是否工作正常,正常時,指示燈為綠色,并且閃爍。如果上面的部分均正常,可用替換法檢查人機界面,先替換控制盒,再替換屏,后替換主機。人機界面正常但電腦不能操作。一臺人機界面,經試驗其本身一切正常,但接上主機后,電腦不能操作。處理:對于這種情況,原因有二。其一,可能是人機界面驅動程序版本過低,需要安裝的驅動程序。其二,可能是在主機啟動裝載人機界面驅動程序之前。b)當I/Is2時,平均誤差不大于5%+30ms。整定起動電流整定:起動電流整定開關為左一組撥碼開關(共兩個),左面一個表示1,右面一個表示0.1。若其值為5和6,則其整定值為5.6A。注意其范圍為無輔助電壓產品2-9.9A,級差是0.1。反時限特性曲線K值整定:K值整定開關為左第三組撥碼開關(共二個),左邊一個為表示1級;右邊一個表示0.1級。本產品K值整定范圍為0.1~9.9,(舉例)比如其值設定為5.0,過流值設定為5.0,輸入實際電流為30A時那么它的延時時間為13.5秒,但其速斷倍數值應設定為6倍以上。速動倍數整定:速動倍數選擇開關為左組撥碼開關。